- Overview
- Specifications
- Brochures
- Technical Data
Atmosphere is an exciting new addition to the façade market, offering infinite variability, measured sustainability outcomes and the ability to retrofit existing buildings, assisting them to achieve energy efficiency.
Atmosphere utilises folded perforated panels combined with tensioned stainless steel cables to create a façade that floats from the building envelope.
Atmosphere utilises folded perforated panels combined with tensioned stainless steel cables to create a façade that floats from the building envelope.
The façade system has been designed to allow internal occupants to have a clear vision of the space outside, while protecting them from the harsh glare of the sun.
The Atmosphere E2 panel achieves the optimum balance of reducing the heat hitting the surface of the glass, while still allowing enough natural daylight to penetrate deep into the internal space.
The Atmosphere E2 panel achieves the optimum balance of reducing the heat hitting the surface of the glass, while still allowing enough natural daylight to penetrate deep into the internal space.
|
The following data is based on analysis of the E1 panel, as performed by GHD, based on a typical curtain wall application for a typical office in Melbourne, Australia. |
|||
| Facade | Action | Irradiation | Reduction |
| North | No shading Device | 1,350,242 Wh/m2 | |
| With Atmosphere | 297,796 Wh/m2 | 77.9% | |
| South | No shading Device | 546,876 Wh/m2 | |
| With Atmosphere | 188,322 Wh/m2 | 65.6% | |
| East | No shading Device | 2951,412 Wh/m2 | |
| With Atmosphere | 243,509 Wh/m2 | 74.4% | |
| West | No shading Device | 946,673 Wh/m2 | |
| With Atmosphere | 255,468 Wh/m2 | 73.0% | |
|
The following savings are based on analysis of the E2 panel, as performed by GHD, based on a typical curtain wall application for a typical office in Melbourne, Australia. Savings include heating, cooling and ventilation. |
|||
| Natural Gas | Electricity | Total Energy | |
| No Atmosphere | $1,017.07 | $12,295.45 | $13,312.53 |
| With Atmosphere | $1,762.69 | $4,493.70 | $7,256.39 |
| +$745.61 | -$6,810.75 | -$6,056.14 | |
| +73.31% | -55.32 % | -45.49% | |
| Potential Cost Savings
based on electricity cost of 19c/kWh and natural gas cost of 0.033c/kWh |
|||
| Natural Gas | Electricity | Total Energy | |
| No Atmosphere | 7.71 t | 80.89 t | 88.59 t |
| With Atmosphere | 13.35 t | 36.14 t | 49.50 t |
| 5.65 t | -44.75 t | -39.10 t | |
| +73.31% | -55.32 % | -44.13% | |
| Potential CO2-e Emission Savings (tonnes) includes heating, ventilation and air conditioning Based on electricity emissions factor of 1.25 kg CO2-e/kWh and natural gas emissions factor of 0.9 tonnes CO2-e /TJ |
next
prev

Curtains
Woven Wire
Perforated
Pic perf
Atmosphere
Expanded
Fixing Systems
Poly
Rubber
Wire
Mobile Screening
Accessories
Product Comparison Grid
Gridforge
Gripspan
Handrail
Gridwalk
Safe T Perf
Shurgrip
FRP Grating
Rural Flooring
Expanded
Conveyor Belts
Expanded Security